Испаритель
Shell & Tube Heat Exchangers
Tanpera TES Series испарительs are dry-expansion shell-and-tube решения designed for high производительность, energy savings, and long сервис life in промышленные and ОВиК chiller packages.
About the Испаритель
Tanpera TES Series испарительs are dry-expansion shell-and-tube решения designed for high производительность, energy savings, and long сервис life in промышленные and ОВиК chiller packages.
Role in the Refrigeration Cycle
The refrigeration cycle consists of four main components: compressor, condenser, expansion valve, and испаритель. The compressor raises the gas давление and температура and sends it to the condenser; the fluid condensed in the condenser reaches the expansion valve. The gas–liquid mixture leaving the valve enters the испаритель; here the refrigerant fully returns to the gas phase, flows back to the compressor, and the cycle is completed.
The success of a cooling система depends directly on efficient испаритель operation; when correctly selected, система производительность and энергоэффективность increase significantly.
TES Series Advantages
High heat-transfer эффективность
Precise температура control
The refrigerant’s transition to vapor phase maintains the desired температура level, enabling stable operation in food, процесс, and ОВиК применения.
Durability and long сервис life
Manufactured with materials and engineering suited to demanding промышленные conditions; EN-compliant mechanical calculations are performed by Tanpera engineers.
Easy монтаж, обслуживание, and flexibility
A compact design simplifies монтаж and обслуживание. With 1–4 independent gas circuits and different capacity and material options, проект-based configuration is available.
Environmentally friendly with wide application range
Key Features
- Dry-expansion TES series shell-and-tube испаритель.
- Standard internally grooved copper tube; copper-nickel / AISI 304L / AISI 316L / carbon steel for special применения.
- Standard R407C; design compatible with HCFC, HFC, and HFO refrigerants.
- 1–4 independent gas circuits; wide operating range for chiller packages.
- Refrigerant-side 33 bar / water-side 11 bar dry-nitrogen test давление.
- Model notation: TES – circuits – shell diameter – nominal capacity (+ baffle / length options).
Монтаж and Пусконаладка
During пусконаладка, air must be fully removed from the piping and испаритель; operation at a перепад давления matching design conditions must be verified.
Do not exceed the recommended maximum water расход; filters that prevent particles from entering the water circuit must be checked regularly. If загрязнение causes давление/capacity loss, очистка by reverse circulation can be performed.
Послепродажное обслуживание
The Tanpera сервис network provides spare parts, gasket sets, filters, and обслуживание throughout the проект life.
Our technical team works with проект teams for on-site пусконаладка, operator training, and fault response.
- Periodic обслуживание, filter and water-quality checks
- Spare parts and gasket supply
- Пусконаладка, training, and on-site техническая поддержка
- Производительность checks and operating recommendations
Часто задаваемые вопросы
It is a теплообменник that acts as a vaporizer in heating or cooling системы. In the refrigeration cycle it follows the compressor, condenser, and expansion valve; the refrigerant fully returns to the gas phase in the испаритель, is sent to the compressor, and the cycle is completed.
TANPERA TES Series units are dry-expansion shell-and-tube испарительs. They are manufactured with standard internally grooved copper tubes and a carbon-steel shell; for special применения they offer copper-nickel or AISI 304L/316L options, 1–4 independent gas circuits, and a wide chiller-compatible capacity range.
It is designed for R407C as standard. Tanpera engineers size it to operate with HCFC, HFC, and HFO refrigerants.
On standard TES испарительs, the refrigerant side is tested at 33 bar and the water side at 11 bar with dry nitrogen. Additional leak tests are applied on 1–4 circuit groups to prevent inter-circuit leaks.
They are used in the food industry, iron and steel casting, air-conditioning and heat-pump системы, cold storage, and промышленные/ОВиК chiller packages.
Water flow and inlet/outlet температура, refrigerant, evaporation/condensation, superheat, and загрязнение factor are the key inputs. Reference tables in the брошюра are based on R407C / 12–7 °C water / 45 °C condensation conditions; Tanpera’s engineering team determines the correct TES model for each проект.
Water flow must not be stopped before the refrigerant is evacuated. During unused periods, water must be drained or the unit filled with antifreeze with no trapped air. The antifreeze ratio is selected for the desired freezing point.
Water-side filters must be checked regularly; water quality and antifreeze ratio should be monitored periodically. If загрязнение causes давление or capacity loss, очистка by reverse circulation can be performed. The продукт must be operated in a horizontal mounting position and below the recommended maximum расход.
You can download or view the English брошюра and user manual as PDF from the Documents tab on the продукт page.
You can submit your проект details via the Quote Form on the продукт page or contact our sales team at sales@tanpera.com. Our engineering team will contact you for capacity and material selection.